rc-discharge-envelope.n3 · input · output · proof · check · try it in the playground
The question
A sampled capacitor model supplies an initial voltage and an upper decay factor. N3 arithmetic rules derive voltage bounds at candidate steps and check when the tolerance is met.
Which candidate step first has a supplied upper-voltage envelope below tolerance?
What we tell Eyeron
The following excerpts use the prefixes declared in the linked source. These are excerpts; the linked file contains the complete program.
# The companion input supplies the decay bound. At each candidate index,
# raise that bound to the index and multiply by the initial voltage.
{
:case :initialVoltage ?Initial ;
:decayUpper ?DecayUpper ;
:candidateStep ?Step .
?Step :index ?Index .
(?DecayUpper ?Index) math:exponentiation ?Factor .
(?Initial ?Factor) math:product ?Voltage .
} => {
?Step :upperVoltage ?Voltage .
} .
{ … } => { … } reads “when the left side holds, conclude the right side.”
Names beginning with ? are variables: they stand for the values that make
the conditions match. The companion input supplies additional facts; load it
together with the rules in the commands below.
What Eyeron concludes
An excerpt of the saved text report:
exact decay symbol : exp(-1/4)
certified decay interval : [0.7788007830, 0.7788007831]
first below tolerance step : 13
first below tolerance time : 0.325 s
upper voltage at step 13 : 0.930581 V
The proof, step by step
eyeron -p records why the conclusions follow. This excerpt is one recorded
step from the saved proof:
{ :step12 :upperVoltage 1.1948896413552061 . }
pe:rule 1;
pe:binding
[ pe:var "DecayUpper"; pe:value 0.7788007831 ],
[ pe:var "Factor"; pe:value 0.04978706838980025 ],
[ pe:var "Index"; pe:value 12 ],
[ pe:var "Initial"; pe:value 24 ],
[ pe:var "Step"; pe:value :step12 ],
[ pe:var "Voltage"; pe:value 1.1948896413552061 ];
pe:uses
{ :case :initialVoltage 24 . },
{ :case :decayUpper 0.7788007831 . },
{ :case :candidateStep :step12 . },
{ :step12 :index 12 . },
{ (0.7788007831 12) math:exponentiation 0.04978706838980025 . },
{ (24 0.04978706838980025) math:product 1.1948896413552061 . }.
pe:rule 1 identifies the source rule used by this step. pe:binding records the values substituted for variables; pe:uses lists the premises the step depends on. Those premises have their own supporting steps in the full proof.
Checked: what the report says
The saved check report gives this verdict and these selected conditions:
# checked: 28 steps, 28 verified, 0 trusted
pe:verdict pe:checked;
pe:condition [ pe:id "C1"; pe:name "resolution"; pe:checked 19; pe:failed 0 ];
pe:condition [ pe:id "C5"; pe:name "re-decision"; pe:checked 9; pe:failed 0 ];
pe:condition [ pe:id "C10"; pe:name "call fidelity"; pe:checked 7; pe:failed 0 ].
Resolution checks that the recorded facts and rule applications match the source program.
Re-decision recomputes the recorded built-in operations.
Call fidelity checks the answer against the question as it was called.
The verdict is checked for the recorded claims. It does not establish that every possible answer was found.
Try it
eyeron examples/rc-discharge-envelope.n3 examples/input/rc-discharge-envelope.trig
eyeron -p examples/rc-discharge-envelope.n3 examples/input/rc-discharge-envelope.trig
eyeron -c examples/rc-discharge-envelope.n3 examples/input/rc-discharge-envelope.trig
Takeaway