decimal-ebike-motor-thermal-envelope.n3 · output · proof · check · try it in the playground
The question
An e-bike climb combines motor heating with cooling toward ambient temperature. N3 arithmetic rules propagate the supplied decimal cooling bounds and check the resulting temperature envelope.
What motor temperatures are allowed by the supplied cooling bounds?
What we tell Eyeron
The following excerpts use the prefixes declared in the linked source. These are excerpts; the linked file contains the complete program.
# Parameters
:ride a :EBikeThermalAssessment ;
:samplePeriod "5.0"^^xsd:decimal ;
:thermalTimeConstant "20.0"^^xsd:decimal ;
:exactCoolingSymbol "exp(-1/4)" ;
…
:initialMotorTemperature "33.0"^^xsd:decimal ;
:warningLimit "35.0"^^xsd:decimal ;
:hardLimit "45.0"^^xsd:decimal ;
:maxStep 12 .
# The decimal interval is a finite certificate for exp(-1/4)
{
:ride :coolingLower ?lo ;
:coolingUpper ?hi .
?lo math:lessThan ?hi .
?lo math:greaterThan 0 .
?hi math:lessThan 1 .
} => {
:ride :coolingCertificate :CertifiedDecimalInterval .
:ride :contractiveCooling true .
} .
{ … } => { … } reads “when the left side holds, conclude the right side.”
Names beginning with ? are variables: they stand for the values that make
the conditions match. The ellipsis omits part of the source; the linked file
contains the full program.
What Eyeron concludes
This is an excerpt of the saved conclusions.
:result :coolingStep 10 .
:result :coolingStep 11 .
:result :coolingStep 3 .
:result :coolingStep 4 .
:result :temperatureTrace (8 :Coast "34.24203310142329"^^xsd:decimal "34.242033106190284"^^xsd:decimal) .
:result :temperatureTrace (9 :Coast "32.197702615900376"^^xsd:decimal "32.19770262053712"^^xsd:decimal) .
The proof, step by step
eyeron -p records why the conclusions follow. This excerpt is one recorded
step from the saved proof:
{ :result :summary ("cooling-symbol" "exp(-1/4)" "cooling-lower" 0.7788007830 "cooling-upper" 0.7788007831 "warning-limit-C" 35.0 "hard-limit-C" 45.0 "warning-recovery-step" 8 "warning-recovery-time-s" "40"^^xsd:decimal "decision" :ThermallySafeForThisAssistPlan) . }
pe:rule
{
{
:ride :exactCoolingSymbol ?sym .
:ride :coolingLower ?aLo .
:ride :coolingUpper ?aHi .
:ride :warningLimit ?warn .
:ride :hardLimit ?hard .
:ride :firstRecoveredWarningAt ?k .
:ride :firstRecoveredWarningTime ?t .
:ride :rideDecision ?decision .
} => {
:result :summary ("cooling-symbol" ?sym "cooling-lower" ?aLo "cooling-upper" ?aHi "warning-limit-C" ?warn "hard-limit-C" ?hard "warning-recovery-step" ?k "warning-recovery-time-s" ?t "decision" ?decision) .
} .
};
pe:binding
[ pe:var "aHi"; pe:value 0.7788007831 ],
[ pe:var "aLo"; pe:value 0.7788007830 ],
[ pe:var "decision"; pe:value :ThermallySafeForThisAssistPlan ],
[ pe:var "hard"; pe:value 45.0 ],
…
{ :ride :hardLimit 45.0 . },
{ :ride :firstRecoveredWarningAt 8 . },
{ :ride :firstRecoveredWarningTime "40"^^xsd:decimal . },
{ :ride :rideDecision :ThermallySafeForThisAssistPlan . }.
pe:binding records the values substituted for variables; pe:uses lists the premises the step depends on. Those premises have their own supporting steps in the full proof. The ellipsis leaves out part of this step.
Checked: what the report says
The saved check report gives this verdict and these selected conditions:
# checked: 210 steps, 210 verified, 0 trusted
pe:verdict pe:checked;
pe:condition [ pe:id "C1"; pe:name "resolution"; pe:checked 94; pe:failed 0 ];
pe:condition [ pe:id "C5"; pe:name "re-decision"; pe:checked 116; pe:failed 0 ];
pe:condition [ pe:id "C10"; pe:name "call fidelity"; pe:checked 435; pe:failed 0 ].
Resolution checks that the recorded facts and rule applications match the source program.
Re-decision recomputes the recorded built-in operations.
Call fidelity checks the answer against the question as it was called.
The verdict is checked for the recorded claims. It does not establish that every possible answer was found.
Try it
eyeron examples/decimal-ebike-motor-thermal-envelope.n3
eyeron -p examples/decimal-ebike-motor-thermal-envelope.n3
eyeron -c examples/decimal-ebike-motor-thermal-envelope.n3
Takeaway
A finite temperature envelope carries uncertainty in the cooling factor through the calculation.