Checking a beam’s bending stress

Four beams, one formula, and a safety verdict for each that a checker recomputes.

beam-bending-safety.n3 · output · proof · check · try it in the playground


The question

A beam rests on two supports and carries a load in the middle. The load bends it, and bending stretches the bottom of the beam and squeezes the top. That bending stress must stay below what the material allows.

Textbook mechanics gives the numbers for a rectangular beam:

Which of four beam designs are safe?


What we tell Eyeron

Four designs, all allowed a stress of 12000. For example:

:FloorBase a :BeamDesign ;
    :description "base floor beam under design load" ;
    :span 3.0 ;
    :pointLoad 5.0 ;
    :width 0.05 ;
    :height 0.2 ;
    :allowableStress 12000.0 .

FloorOverload is the same beam with a load of 10.0; FloorTall has the base load on a beam 0.3 tall; ShelfLight is a short shelf with a light load.

The formulas are backward rules, written with <=: the conclusion comes first, and Eyeron works it out only when something asks for it.

{
    ?B :sectionModulus ?S .
} <= {
    ?B a :BeamDesign ;
        :width ?b ;
        :height ?h .

    (?h 2) math:exponentiation ?h2 .
    (?b ?h2) math:product ?bh2 .
    (?bh2 6.0) math:quotient ?S .
} .

The math: predicates are built-ins that compute: (?h 2) math:exponentiation ?h2 squares the height.


Safe or not, and what to print

Two rules decide the verdict, one for each side of the limit:

{
    ?B :isSafe true .
} <= {
    ?B :bendingStress ?sigma ;
        :allowableStress ?allow .
    ?sigma math:notGreaterThan ?allow .
} .

The program ends with three queries. log:query says which statements to print, and asking them is what sets the backward rules in motion:

{
    ?Subject :isSafe ?Value .
} log:query {
    ?Subject :isSafe ?Value .
} .

What Eyeron concludes

:ShelfLight :bendingStress 8333.333333333334 .
:FloorBase :bendingStress 11249.999999999996 .
:FloorOverload :bendingStress 22499.999999999993 .
:FloorTall :bendingStress 5000.000000000001 .
:ShelfLight :safetyFactor 1.44 .
:FloorBase :safetyFactor 1.066666666666667 .
:FloorOverload :safetyFactor 0.5333333333333335 .
:FloorTall :safetyFactor 2.3999999999999995 .
:ShelfLight :isSafe true .
:FloorBase :isSafe true .
:FloorTall :isSafe true .
:FloorOverload :isSafe false .

The base floor beam is just safe, with a factor of about 1.07. Doubling the load doubles the stress, to almost twice the limit. Making the beam 1.5 times taller instead cuts the stress to 5000, because resistance grows with the square of the height. The odd trailing digits are floating-point rounding.

The intermediate moments and section moduli are not printed: the queries do not ask for them.


The proof, step by step

Each answer unfolds into the chain of formulas behind it. The shelf’s stress, for instance, is rule 3 applied to a moment and a section modulus:

{ :ShelfLight :bendingStress 8333.333333333334 . }
  pe:rule 3;
  …
  pe:uses
    { :ShelfLight :maxMoment 0.2 . },
    { :ShelfLight :sectionModulus 0.000024 . },
    { (0.2 0.000024) math:quotient 8333.333333333334 . }.

and the moment in turn comes from rule 1, the given facts and two calculations:

{ :ShelfLight :maxMoment 0.2 . }
  pe:rule 1;
  …
  pe:uses
    { :ShelfLight a :BeamDesign . },
    { :ShelfLight :span 0.8 . },
    { :ShelfLight :pointLoad 1.0 . },
    { (1.0 0.8) math:product 0.8 . },
    { (0.8 4.0) math:quotient 0.2 . }.

The failing verdict is just as explicit:

{ :FloorOverload :isSafe false . }
  pe:rule 6;
  …
    { 22499.999999999993 math:greaterThan 12000.0 . }.

In all: 71 steps, of which 20 rule steps, 24 facts and 27 built-in results.


Checked: what the report says

# checked: 71 steps, 71 verified, 0 trusted
pe:verdict pe:checked;
pe:condition [ pe:id "C1"; pe:name "resolution"; pe:checked 44; pe:failed 0 ];
pe:condition [ pe:id "C5"; pe:name "re-decision"; pe:checked 27; pe:failed 0 ];
pe:condition [ pe:id "C10"; pe:name "call fidelity"; pe:checked 112; pe:failed 0 ].

Nothing is taken on trust, so the verdict is checked. It confirms the arithmetic and the verdicts under this simple model; it says nothing about whether the model fits a real beam.


Try it

eyeron examples/beam-bending-safety.n3      # the answers
eyeron -p examples/beam-bending-safety.n3   # with the proof
eyeron -c examples/beam-bending-safety.n3   # the proof, checked

Give FloorOverload a height of 0.3 instead of 0.2: its stress drops to 10000 and it becomes safe, with a factor of about 1.2.


Takeaway

Backward rules let formulas be written once and computed on demand; the proof keeps every intermediate number, and the checker redoes each one.