Two machine settings computed from sensor readings, with every sum shown.
control-system.js · output · proof · check · try it in the playground
The question
A controller reads sensors and decides how hard to drive its actuators (the parts that act: a valve, a motor, a heater).
This example computes commands for two actuators:
- Actuator 1 pushes in proportion to a measurement, minus a correction for a disturbance it can measure in advance (feedforward: compensate before the disturbance shows up in the output).
- Actuator 2 reacts to the gap between a target and the actual output (feedback: correct based on the error you see).
What should each command be, and how was it worked out?
What we tell eyecode: the readings
fact(measurement1('input1', [6, 11]))
fact(measurement2('input2', 'true'))
fact(measurement3('disturbance1', 35766))
fact(measurement4('output2', 24))
fact(observation3('state3', 22))
fact(target2('output2', 29))
// …
A pair like [6, 11] is turned into one number by a helper rule: if the first
value is smaller, use the square root of the difference (here √5); otherwise
use the first value.
What we tell eyecode: actuator 1
implied_by(
control1('actuator1', C),
[
measurement10('input1', M1),
measurement2('input2', 'true'),
measurement3('disturbance1', D1),
gt(D1, 0), // the logarithm needs a positive disturbance
is(C1, mul(M1, 19.6)), // proportional part
is(C2, div(log(D1), log(10))), // compensation part: log10 of the disturbance
is(C, sub(C1, C2)), // simple feedforward control
],
)
is means “calculate”: it binds its first argument to the value of the
arithmetic term (mul, div, sub, log) in its second. The compensation
is the base-10 logarithm of the disturbance, so the rule first checks with
gt that the disturbance is positive: a logarithm of zero or less would stop
the run with an error.
What we tell eyecode: actuator 2
implied_by(
control1('actuator2', C),
[
observation3('state3', P3),
measurement4('output2', M4),
target2('output2', T2),
is(E, sub(T2, M4)), // error: target minus output
is(D, sub(P3, M4)), // differential error: observed state minus output
is(C1, mul(5.8, E)), // proportional part
nonlinear_part(E, D, C2), // nonlinear differential part
is(C, add(C1, C2)), // PND feedback control
],
)
Guarding a division
implied_by(
nonlinear_part(E, D, C2),
[
ne(E, 0),
is(N, div(7.3, E)), // nonlinear factor
is(C2, mul(N, D)),
],
)
implied_by(nonlinear_part(E, _, 0), eq(E, 0))
The nonlinear factor divides by the error. On target the error is zero, and the division would stop the run, so two exclusive clauses split the cases: with an error, the factor is computed; without one, the nonlinear part is left out.
What eyecode concludes
control1('actuator1', 39.27346198678276)
control1('actuator2', 26.08)
These are ordinary decimal (floating-point) numbers, printed in full.
Why: the proof in plain words
Actuator 1
- 6 < 11, so the input is √(11 − 6) = √5 = 2.23606797749979.
- Proportional part: 2.236… × 19.6 = 43.82693235899588.
- Compensation: log₁₀(35766) = 4.553470372213121.
- Command: 43.826… − 4.553… = 39.27346198678276.
Actuator 2
- Error 29 − 24 = 5; differential error 22 − 24 = −2.
- Proportional part 5.8 × 5 = 29.0; factor 7.3 / 5 = 1.46.
- Differential part 1.46 × −2 = −2.92; command 29.0 − 2.92 = 26.08.
Every one of these values is written into the proof.
Checked, not just claimed
The checker does not take the arithmetic on faith: it recomputes each calculation itself and compares.
- 24 steps: 10 verified against the program lines they cite, and 14 calculations and comparisons recomputed and found to agree.
- No circular reasoning, every claim justified, nothing extra.
- 0 steps taken on trust.
Verdict: checked.
Try it
eyecode examples/control-system.js # the commands
eyecode --proof examples/control-system.js # answers with their proof
Or open it in the playground.
Raise the target to fact(target2('output2', 34)) and run again: the error becomes
10, and actuator 2’s command becomes 56.54 instead of 26.08. Actuator 1 is
unchanged. Set the target to 24, the current output: the error is zero, the
nonlinear part is left out, and the command is 0.0. Set the disturbance to
0: actuator 1 gets no command, since its compensation is undefined, and
actuator 2 is unaffected.
Takeaway
When a machine setting comes from a chain of formulas, a proof that lists and re-checks every intermediate value turns “the controller said so” into something an engineer can audit line by line.